"/api/v1/link/put": {"post": {
|
|
"summary": "Send one sealed message through a device link",
|
|
"description": "Body: {\"id\": 32 lowercase hex link ID shown in a QR code, \"slot\": \"request\" or \"response\", \"data\": sealed text up to 16384 bytes}. Each slot is written once. Links expire ten minutes after their first message. Messages are sealed between the two devices; the node relays them without reading them.",
|
|
"responses": {"200": {"description": "Message stored"}, "400": {"description": "Invalid link, slot or message"}, "409": {"description": "Slot already written"}, "429": {"description": "Rate limit exceeded"}}
|
|
}},
|
|
"/api/v1/link/get": {"post": {
|
|
"summary": "Read a device link slot",
|
|
"description": "Body: {\"id\", \"slot\"}. Returns {\"data\"} once the other device has written the slot.",
|
|
"responses": {"200": {"description": "Sealed message"}, "404": {"description": "Waiting for the other device, or the link expired"}, "429": {"description": "Rate limit exceeded"}}
|
|
}},
|
|
"/api/v1/link/close": {"post": {
|
|
"summary": "Forget a device link",
|
|
"description": "Body: {\"id\"}. Either device closes the link once it is connected or cancelled.",
|
|
"responses": {"200": {"description": "Link removed"}, "400": {"description": "Invalid link"}}
|
|
}}
|
|
}
|